| Fold back the floor covering until the condensation water drain -4- is visible. |
–
| Cover the area below the opening -1- with absorbant paper. |
–
| Carefully pull off the connection angle -2- from the air conditioning unit -1- and the connection -4- from the opening -5-. |
–
| Check the condensation water drain -1- and -4- for contamination; e.g. with a piece of wire. |
Note t
| The connecting pieces -2- and -4- must fit tightly on the pipe -3-. |
t
| When installing pay attention to the correct positioning of the connecting pieces -2- and -4- in the areas -1- and -5- (torsion stop). |
|
|
|